Data Centre Services

The first and only purpose-built,
Tier III-certified data centre in Malaysia for security,
redundancy, monitoring and uptime.

A conducive environment for your server’s needs

High availability

Our Service Level Availability of 99.985% means you spend more time running your business.

Carrier neutral

Multi ISP is available for improved availability & flexibility.

State-of-the-art infrastructure

Solid reliability for day-to-day operations, mission-critical projects, back-up and disaster recovery.

Key features of Maxis Data Centres

Air conditioning
The air conditioning systems are air-cooled to prevent condensation in the data centre. Controlled temperature of 22-24 °C with 50% humidity to ensure cooling efficiency R410A refrigerant – extra 15% cooling capacity compared to standard refrigerant.

Power source
Redundant dual 11 kV power source from 2 different substations. Power supply of 100 W/ft2, upgradable to 200W/ft2. 2N of active power distribution paths to each rack. 2 groups of 4 units of 100 kVA UPS with 10 minutes of back-up battery.

Security
The facility is equipped with 24/7 surveillance and CCTV monitoring, access is secured with biometric fingerprint scanning.

Fire suppression system
Environment-friendly inert gas IG 55 fire suppression system with VESDA (Very Early Smoke Detection Apparatus) and comprehensive detection monitoring system.

Connectivity
Carrier-neutral, with a full range of data connectivity and services and access to multiple providers to ensure full network redundancy.

Green Initiatives
Our infrastructure is optimised to be environment-friendly:

LED Lighting

  • Produces as much brightness as regular lights with lower electricity consumption.

Lighting Control

  • Saves power by switching off lights when no human presence is detected.

R410A Refrigerant

  • Extra 15% cooling capacity compared to standard gas.

Temperature Control

  • Rack level temperature control to ensure cooling efficiency.

Why does certification matter?

Maxis Data Centre is Tier III-certified. This certification process is conducted by the Uptime Institute, industry experts who
authenticate our data centre’s commitment level, and to verify that policies and procedures are actually carried out.

 These data centre tier certifications are the standard guiding design and investment for data centres globally.

Tier I

Tier I is composed of a single path for power and cooling distribution, without redundant components, providing 99.671% availability.

Tier II

Tier II is composed of a single path for power and cooling distribution, with redundant components, providing 99.741% availability.

Tier III

Tier III is composed of multiple active power and cooling distribution paths. However only one path is used, has redundant components and is concurrently maintainable, providing 99.985% availability.

Tier IV

Tier IV is composed of multiple active power and cooling distribution paths, with all having redundant components and fault tolerant, providing 99.995% availability.

Maxis Data Centre Services

Managed network service

  • Dedicated internet access
  • IP VPN
  • MPLS

Co-location service

  • Dedicated DC private cages
  • Dedicated DC racks
  • Telehousing services

Value-added services

  • Disaster recovery service
  • Managed hosting service
  • Managed security service

Cloud computing

  • IaaS (Infrastructure-as-a-Service)
  • SaaS (Software-as-a-Service)

 

Let's talk business

Got an enquiry on any of our Business Solution? Contact our representatives at 1800-82-1919 or leave your contact details with us and we'll call you.

 

This field is required
This field is required
This field is required
60
This field is required
 

By clicking “Agree & submit” you confirm that you have read, agreed and hereby consent to the collection and processing of your personal information/personal data in accordance with the Maxis Privacy Statement and the information you have provided is accurate and correct.